Integrator-based Filters
We can convert passive RLC filters into integrator-based active filters in a systematic way using signal flow graphs.
Contents
- 1 Signal Flow Graphs
- 2 Examples
- 3 Example: A First-Order Low-Pass Filter
- 4 Example: A Second-Order RLC Filter
- 5 Example: A 5th-Order Butterworth Low-Pass Filter
- 6 Differential Integrators
- 7 Maximizing Dynamic Range
- 8 Noise Analysis
- 9 Transmission Zeros
- 10 Example: A 5th-Order Filter with Transmission Zeros
Signal Flow Graphs
Signal flow graphs (SFGs) are topological representations of electrical circuits with two components: (1) nodes, and (2) branches. Any network that can be described by a set of linear differential equations can be represented by a SFG. In a SFG, the nodes represent the variables, e.g. voltages or currents, and the branches represent transfer functions between these node variables, specified by branch multiplication factors (BMFs). These BMFs are obtained from Kirchhoff's equations (KVL and KCL). Note that the branches are directed, as indicated by the arrows. Figs. 1-3 shows a few examples of SFG nodes and branches.
Useful SFG Properties
We can use the following properties to transform signal flow graphs into forms that can allow us to convert passive RLC filters into its active integrator-based counterparts.
Parallel Branches
For two or more parallel branches between two nodes in the same direction, as seen in Fig. 4, the effective branch multiplication factor becomes:
-
(1)
-
Node Absorption
We can also remove intermediate nodes as shown in Fig. 5:
-
(2)
-
Branch Scaling
Node values in Fig. 6 can be scaled by a factor , but with the corresponding changes on the incoming and outgoing branch:
-
(3)
-
Loops
For the loop shown in Fig. 7, we get:
-
(4)
-
Examples
Example: A First-Order Low-Pass Filter
Consider the RC filter shown in Fig. 8. To convert this passive filter into its active equivalent, we can go through the following steps:
Step 1: Name all the voltages and current
All the component voltages and currents are named, as seen in Fig. 8.
Step 2: Use KCL/KVL to obtain the integrator forms
We can get the integrator forms of the reactive components by writing the capacitor voltages as:
-
(5)
-
And the inductor currents as:
-
(6)
-
Thus, for the simple RC filter, we can write out the voltages as:
-
(7)
-
And the currents as:
-
(8)
-
Step 3: Construct the SFG
To systematically construct the signal flow graph, let us create the voltage nodes on the top row, and below them, their corresponding current nodes, as shown in Fig. 9. We can then add the branches, starting with the capacitor branch in its integrator form. We then get one possible SFG (Fig. 9).
Step 4: Normalization
The normalization step converts all the current nodes into voltage nodes using a scaling resistance, , as shown in Fig. 10, converting and into and .
We can then simplify the SFG by combining nodes and as seen in Fig. 11, and by choosing . We then get the SFG in Fig. 12.
We then convert the SFG into its integrator-based equivalent, as shown in Fig. 13. By inverting the input, i.e. multiplying the input by (Fig. 14), and moving the summation into a two-input integrator (Fig. 15), we can easily match this structure to a 2-input op-amp-based integrator (which is presented here), as shown in Fig. 16.
The transfer function, as expected, is equal to:
-
(9)
-
We can also calculate the total integrated output noise (as derived here):
-
(10)
-