Difference between revisions of "Passive Matching Networks"

From Microlab Classes
Jump to navigation Jump to search
 
(13 intermediate revisions by the same user not shown)
Line 13: Line 13:
  
 
=== Series RC Circuit ===
 
=== Series RC Circuit ===
[[File:RC Qseries.png|thumb|500px|Figure 1: A lossy capacitor.]]
+
[[File:RC Qseries.png|thumb|400px|Figure 1: A lossy capacitor.]]
  
 
A lossy capacitor, shown in Fig. 1, can be modeled as a series RC circuit with the series resistance, <math>R_S</math>, could represent the series loss due to interconnect resistances. Thus, the admittance of the lossy capacitor can be expressed as  
 
A lossy capacitor, shown in Fig. 1, can be modeled as a series RC circuit with the series resistance, <math>R_S</math>, could represent the series loss due to interconnect resistances. Thus, the admittance of the lossy capacitor can be expressed as  
Line 37: Line 37:
  
 
=== RL Circuits ===
 
=== RL Circuits ===
[[File:RL Qseries.png|thumb|500px|Figure 2: A lossy inductor.]]
+
[[File:RL Qseries.png|thumb|400px|Figure 2: A lossy inductor.]]
  
 
Applying the ideas above to RL circuits in Fig. 2, we can get the admittance of a series RL circuit as:
 
Applying the ideas above to RL circuits in Fig. 2, we can get the admittance of a series RL circuit as:
Line 56: Line 56:
  
 
=== General Case ===
 
=== General Case ===
[[File:Generic Qseries.png|thumb|500px|Figure 3: A lossy reactance.]]
+
[[File:Generic Qseries.png|thumb|400px|Figure 3: A lossy reactance.]]
  
 
In general, for a reactance <math>X_S</math> in series with a resistance <math>R_S</math>,
 
In general, for a reactance <math>X_S</math> in series with a resistance <math>R_S</math>,
Line 118: Line 118:
  
 
== Basic Matching Networks ==
 
== Basic Matching Networks ==
[[File:Matching block diagram.png|thumb|500px|Figure 4: An impedance matching network.]]
+
[[File:Matching block diagram.png|thumb|400px|Figure 4: An impedance matching network.]]
 
We can use our series-parallel conversions to increase or decrease resistances based on the quality factor. Consider the circuit in Fig. 4, where we want to match the source resistance, <math>R_S</math> to a load resistance, <math>R_L</math> using a lossless matching network, i.e. a network make up of only reactances.
 
We can use our series-parallel conversions to increase or decrease resistances based on the quality factor. Consider the circuit in Fig. 4, where we want to match the source resistance, <math>R_S</math> to a load resistance, <math>R_L</math> using a lossless matching network, i.e. a network make up of only reactances.
  
Line 132: Line 132:
 
{{NumBlk|::|<math>X_1^\prime = X_1 \frac{1}{\left(1 + \frac{1}{Q^2}\right)} \approx X_1</math>|{{EquationRef|30}}}}
 
{{NumBlk|::|<math>X_1^\prime = X_1 \frac{1}{\left(1 + \frac{1}{Q^2}\right)} \approx X_1</math>|{{EquationRef|30}}}}
  
Thus, to keep the impedance seen by the source purely resistive, we can cancel out the reactance <math>X_1^\prime</math> by the reactance <math>X_2 = -X_1^\prime \approx -X_1</math>. Note that the negative sign relating <math>X_1</math> and <math>X_2</math> means that if <math>X_1</math> is a capacitance, then <math>X_2</math> should be an inductance, and vice-versa. For the case when <math>R_S>R_L</math>, we just flip the circuit and the equations would still hold.
+
Thus, to keep the impedance seen by the source purely resistive, we can cancel out the reactance <math>X_1^\prime</math> by the reactance <math>X_2 = -X_1^\prime \approx -X_1</math>. Note that the negative sign relating <math>X_1</math> and <math>X_2</math> means that if <math>X_1</math> is a capacitance, then <math>X_2</math> should be an inductance, and vice-versa. Note that cancelling reactances at resonance could cause large voltages to appear across (or large currents through) the reactances. See this note on [[Resonance | resonance]] for more details. For the case when <math>R_S>R_L</math>, we just flip the circuit and the equations would still hold.
  
 
=== Design Example ===
 
=== Design Example ===
Line 148: Line 148:
  
 
== Loss in Matching Networks ==
 
== Loss in Matching Networks ==
[[File:Lossy L match.png|thumb|500px|Figure 6: A lossy L-section.]]
+
[[File:Lossy L match.png|thumb|400px|Figure 6: A lossy L-section.]]
 
In typical real matching networks, the series resistance of the inductor is the dominant loss mechanism. We can model this loss using a resistor <math>R_2</math> in series with the inductor <math>L_2</math>, as shown in Fig. 6.
 
In typical real matching networks, the series resistance of the inductor is the dominant loss mechanism. We can model this loss using a resistor <math>R_2</math> in series with the inductor <math>L_2</math>, as shown in Fig. 6.
  
Line 167: Line 167:
 
{{NumBlk|::|<math>\mathrm{IL}=\frac{P_L}{P_\mathrm{in}}=\frac{1}{\mathrm{Loss}}</math>|{{EquationRef|36}}}}
 
{{NumBlk|::|<math>\mathrm{IL}=\frac{P_L}{P_\mathrm{in}}=\frac{1}{\mathrm{Loss}}</math>|{{EquationRef|36}}}}
  
If instead, we use an inductor, <math>L_1</math>, in parallel with <math>R_L</math>, we can transform the series resistance <math>R_1</math> into its parallel equivalent, <math>R_1^\prime = R_1\left(1 + Q_L^2\right)</math>, and then calculate the loss as:
+
If we define the inductor component quality factor as <math>Q_c = \tfrac{\omega L_2}{R_2}</math>, with <math>Q = \omega C_1 R_L =\tfrac{1}{\omega C_1^\prime R_L^\prime}</math> and <math>\omega^2 = \tfrac{1}{L_2 C_1^\prime}</math>, we can express the loss as:
  
{{NumBlk|::|<math>\mathrm{Loss} = \frac{P_{\mathrm{in}}}{P_L}= \frac{V_\mathrm{out}^2}{R_1^\prime \| R_L} \frac{R_L}{V_\mathrm{out}^2} = \frac{R_1^\prime + R_L}{R_1^\prime} = 1 + \frac{R_L}{R_1^\prime} = 1 + \frac{R_L}{R_1\left(1 + Q_L^2\right)}</math>|{{EquationRef|37}}}}
+
{{NumBlk|::|<math>\mathrm{Loss} = 1 + \frac{R_2}{R_L^\prime} = 1 + \frac{\frac{\omega L_2}{Q_c}}{\frac{1}{\omega C_1^\prime Q}}=1 + \frac{Q}{Q_c}</math>|{{EquationRef|37}}}}
  
 
== T- and <math>\Pi</math>-Matching Networks ==
 
== T- and <math>\Pi</math>-Matching Networks ==
[[File:Pi match.png|thumb|300px|Figure 7: A <math>\Pi<math>-matching network.]]
+
[[File:Pi match.png|thumb|400px|Figure 7: A <math>\Pi</math>-matching network.]]
  
Single L-section matching circuits are simple and elegant. However, we cannot choose the value of <math>Q</math> since it is determined by <math>m = \tfrac{R_\mathrm{hi}}{R_\mathrm{lo}}</math>. One way to increase the value of <math>Q</math> is to use two L-sections and an low intermediate resistance, <math>R_i</math>, where <math>R_i<R_S</math> and <math>R_i<R_L</math>, as shown in the <math>\Pi</math>-network below.  
+
Single L-section matching circuits are simple and elegant. However, we cannot choose the value of <math>Q</math> since it is determined by <math>m = \tfrac{R_\mathrm{hi}}{R_\mathrm{lo}}</math>. One way to increase the value of <math>Q</math> is to use two L-sections and an low intermediate resistance, <math>R_i</math>, where <math>R_i<R_S</math> and <math>R_i<R_L</math>, as shown in the <math>\Pi</math>-network in Fig. 7.  
  
 
The first L-section reduces the value of source resistance, <math>R_S</math>, to the intermediate resistance, <math>R_i</math>, and the second L-section brings resistance from <math>R_i</math> to <math>R_L</math>.  
 
The first L-section reduces the value of source resistance, <math>R_S</math>, to the intermediate resistance, <math>R_i</math>, and the second L-section brings resistance from <math>R_i</math> to <math>R_L</math>.  
Line 184: Line 184:
 
{{NumBlk|::|<math>Q_2 = \sqrt{\frac{R_L}{R_i} - 1} = \frac{X_2}{R_i}=\frac{R_L}{X_2^\prime}</math>|{{EquationRef|39}}}}
 
{{NumBlk|::|<math>Q_2 = \sqrt{\frac{R_L}{R_i} - 1} = \frac{X_2}{R_i}=\frac{R_L}{X_2^\prime}</math>|{{EquationRef|39}}}}
  
From fig. , the overall <math>Q</math> can be calculated as:
+
[[File:Pi match Q.png|thumb|400px|Figure 8: Calculating the overall <math>Q</math> of a <math>\Pi</math>-network.]]
 +
 
 +
From Fig. 8, the overall <math>Q</math> can be calculated by converting the parallel circuits into their series equivalents. Therefore:
  
 
{{NumBlk|::|<math>Q = \frac{X_1 + X_2}{2R_i} = \frac{Q_1 + Q_2}{2}</math>|{{EquationRef|40}}}}
 
{{NumBlk|::|<math>Q = \frac{X_1 + X_2}{2R_i} = \frac{Q_1 + Q_2}{2}</math>|{{EquationRef|40}}}}
  
If we want an intermediate resistance, <math>R_i</math>, that is larger than both <math>R_S</math> and <math>R_L</math>, we can use a T-network instead of a <math>\Pi</math>-network, as shown below.  
+
[[File:T match.png|thumb|400px|Figure 9: A T-matching network.]]
 +
If we want an intermediate resistance, <math>R_i</math>, that is larger than both <math>R_S</math> and <math>R_L</math>, we can use a T-network instead of a <math>\Pi</math>-network, as shown in Fig. 9.  
  
 
In this case,  
 
In this case,  
Line 199: Line 202:
  
 
== Multi-Section Low-<math>Q</math> Matching ==
 
== Multi-Section Low-<math>Q</math> Matching ==
T- and <math>\Pi</math>-networks are used to increase the overall <math>Q</math>. However, in some applications, a lower <math>Q</math> is required, especially in broadband circuits. Low <math>Q</math> circuits are also more robust to process variations and have relatively lower losses. To lower the quality factor of a matching network, we can cascade L-sections with an intermediate resistance, <math>R_\mathrm{hi}>R_i>R_\mathrm{lo}</math>, as shown in fig. for <math>R_S>R_L</math>.
+
[[File:LowQ match.png|thumb|400px|Figure 10: A low-<math>Q</math> cascaded-L matching network.]]
 +
 
 +
T- and <math>\Pi</math>-networks are used to increase the overall <math>Q</math>. However, in some applications, a lower <math>Q</math> is required, especially in broadband circuits. Low <math>Q</math> circuits are also more robust to process variations and have relatively lower losses. To lower the quality factor of a matching network, we can cascade L-sections with an intermediate resistance, <math>R_\mathrm{hi}>R_i>R_\mathrm{lo}</math>, as shown in Fig. 10 for <math>R_S<R_L</math>.
  
 
The quality factor can be expressed as
 
The quality factor can be expressed as
  
{{NumBlk|::|<math>Q = \frac{1}{2}\left(\sqrt{\frac{R_S}{R_i} - 1} + \sqrt{\frac{R_i}{R_L} - 1}\right)</math>|{{EquationRef|43}}}}
+
{{NumBlk|::|<math>Q = \frac{1}{2}\left(Q_1 + Q_2\right) =\frac{1}{2}\left(\sqrt{\frac{R_i}{R_S} - 1} + \sqrt{\frac{R_L}{R_i} - 1}\right)</math>|{{EquationRef|43}}}}
  
 
To get the minimum possible <math>Q</math>, we can take the derivative of eq. 43 with respect to <math>R_i</math> and equate it to zero. This results in the optimum intermediate resistance:
 
To get the minimum possible <math>Q</math>, we can take the derivative of eq. 43 with respect to <math>R_i</math> and equate it to zero. This results in the optimum intermediate resistance:

Latest revision as of 14:36, 16 September 2020

Controlling impedances in radio-frequency (RF) circuits is essential in order to maximize power transfer between blocks and to reduce reflections caused by impedance discontinuities along a signal path. In this module, we will define the quality factor, , for a device or a circuit, and use this to build circuits that modify the impedance seen across a port.

Device Quality Factor

The quality factor, , is a measure of how good a device is at storing energy. Thus, the lower the losses, the higher the . In general, if we can express the impedance or admittance of a device as

 

 

 

 

(1)

The quality factor can then be expressed as

 

 

 

 

(2)

The imaginary component, represents the energy storage element, and the real component, , represents the loss (resistive) component.

Series RC Circuit

Figure 1: A lossy capacitor.

A lossy capacitor, shown in Fig. 1, can be modeled as a series RC circuit with the series resistance, , could represent the series loss due to interconnect resistances. Thus, the admittance of the lossy capacitor can be expressed as

 

 

 

 

(3)

We can therefore express the quality factor of the series circuit as:

 

 

 

 

(4)

Note that for the lossless case, , and consequently .

Parallel RC Circuit

A lossy capacitor can also be modeled as a parallel RC circuit, with the parallel resistance, could represent the energy loss due to the dielectric leakage of the capacitor. In this case, we can write the impedance of the circuit as:

 

 

 

 

(5)

Thus, the quality factor is:

 

 

 

 

(6)

We can see that in the lossless case, , corresponding to .

RL Circuits

Figure 2: A lossy inductor.

Applying the ideas above to RL circuits in Fig. 2, we can get the admittance of a series RL circuit as:

 

 

 

 

(7)

with quality factor:

 

 

 

 

(8)

Similarly, for parallel RL circuits, the impedance and quality factor can be expressed as:

 

 

 

 

(9)

 

 

 

 

(10)

Note that the quality factor is frequency dependent, and for or , we get the ideal case where or respectively.

General Case

Figure 3: A lossy reactance.

In general, for a reactance in series with a resistance ,

 

 

 

 

(11)

 

 

 

 

(12)

and for a reactance in parallel with a resistance ,

 

 

 

 

(13)

 

 

 

 

(14)

Series-Parallel Conversions

It is very convenient to be able to convert the series RC or RL circuit to its parallel equivalent or vice-versa, especially in the context of matching circuits. If we equate the parallel and series impedances, , we get

 

 

 

 

(15)

 

 

 

 

(16)

 

 

 

 

(17)

We can look at the imaginary and real components separately. For the real components:

 

 

 

 

(18)

 

 

 

 

(19)

And for the imaginary components:

 

 

 

 

(20)

Using eq. 18 and eq. 20, we get:

 

 

 

 

(21)

 

 

 

 

(22)

We can use eqs. 18 and 22 to get the relationship between the series and parallel reactances:

 

 

 

 

(23)

 

 

 

 

(24)

Rewriting eq. 24 and for :

 

 

 

 

(25)

Key Results:
  • The quality factor is the same for the parallel and series circuits when the impedances are the same.

 

 

 

 

(26)

  • The parallel resistance is larger than the series resistance.

 

 

 

 

(27)

  • The parallel reactance is approximately equal to the series reactance for .

 

 

 

 

(28)

Basic Matching Networks

Figure 4: An impedance matching network.

We can use our series-parallel conversions to increase or decrease resistances based on the quality factor. Consider the circuit in Fig. 4, where we want to match the source resistance, to a load resistance, using a lossless matching network, i.e. a network make up of only reactances.

L-Section Matching Circuits

Figure 5: An L-Section matching network and the network after the parallel-to-serial transformation of and .

Consider the circuit in Fig. 5, and assume . We can use our parallel-series transformations to convert the parallel circuit into a series circuit so that the the series resistance is equivalent to the source resistance,

 

 

 

 

(29)

Where . The reactance also gets transformed into:

 

 

 

 

(30)

Thus, to keep the impedance seen by the source purely resistive, we can cancel out the reactance by the reactance . Note that the negative sign relating and means that if is a capacitance, then should be an inductance, and vice-versa. Note that cancelling reactances at resonance could cause large voltages to appear across (or large currents through) the reactances. See this note on resonance for more details. For the case when , we just flip the circuit and the equations would still hold.

Design Example

Let define the matching factor , where and . Therefore for , and . We can then use eq. 29 to solve for the value of , , and :

 

 

 

 

(31)

If we use a capacitor for , then . Thus, we need an inductance, . Solving for :

 

 

 

 

(32)

Note that matching circuit is narrowband since the perfect cancellation occurs at only one frequency, .

Instead of a capacitor, we can place an inductor in parallel with the larger resistance, and use a series capacitor to cancel out the series equivalent inductance. However, in this case, the capacitor will block any DC and low-frequency signals.

Loss in Matching Networks

Figure 6: A lossy L-section.

In typical real matching networks, the series resistance of the inductor is the dominant loss mechanism. We can model this loss using a resistor in series with the inductor , as shown in Fig. 6.

To determine the power loss due to , we first calculate the power delivered by the input source:

 

 

 

 

(33)

Then we calculate the power delivered to the load, :

 

 

 

 

(34)

We can then define power loss as

 

 

 

 

(35)

Note that the loss is dependent on the ratio of to . Thus, even if is small, can be relatively small as well, depending on the value of . In some cases, it is more convenient to use the inverse of eq. 35, or commonly known as Insertion Loss (IL):

 

 

 

 

(36)

If we define the inductor component quality factor as , with and , we can express the loss as:

 

 

 

 

(37)

T- and -Matching Networks

Figure 7: A -matching network.

Single L-section matching circuits are simple and elegant. However, we cannot choose the value of since it is determined by . One way to increase the value of is to use two L-sections and an low intermediate resistance, , where and , as shown in the -network in Fig. 7.

The first L-section reduces the value of source resistance, , to the intermediate resistance, , and the second L-section brings resistance from to .

We can then compute the quality factor of the two L-sections as:

 

 

 

 

(38)

 

 

 

 

(39)

Figure 8: Calculating the overall of a -network.

From Fig. 8, the overall can be calculated by converting the parallel circuits into their series equivalents. Therefore:

 

 

 

 

(40)

Figure 9: A T-matching network.

If we want an intermediate resistance, , that is larger than both and , we can use a T-network instead of a -network, as shown in Fig. 9.

In this case,

 

 

 

 

(41)

 

 

 

 

(42)

Similar to the -network, the overall T-network quality factor is .

Multi-Section Low- Matching

Figure 10: A low- cascaded-L matching network.

T- and -networks are used to increase the overall . However, in some applications, a lower is required, especially in broadband circuits. Low circuits are also more robust to process variations and have relatively lower losses. To lower the quality factor of a matching network, we can cascade L-sections with an intermediate resistance, , as shown in Fig. 10 for .

The quality factor can be expressed as

 

 

 

 

(43)

To get the minimum possible , we can take the derivative of eq. 43 with respect to and equate it to zero. This results in the optimum intermediate resistance:

 

 

 

 

(44)

Which leads to the minimum quality factor for two cascaded L-sections:

 

 

 

 

(45)

Activity A1.2 Passive Matching Networks -- This activity walks you through the steps in designing and simulating passive matching networks.